Professional Series

(1P/1P) Tower 1kVA/6 KVA

  • True on-line double-conversion technology.
  • Single phase input and single phase output system.
  • High DC charging current for long back-up application.
  • Galvanic isolation design available to provide adequate isolation

 
 

Product Overview

The Professional Series (1P/1P) - Tower is an advanced, affordable on-line double-conversion technology single-phase UPS system. Tower versions are available with 1000VA to 6000VA models and these offer high reliability for workstations, server and network equipment.
The Professional Series is designed with automatic voltage regulation (AVR) to protect against power outages, disturbances and spikes. High voltage battery chargers and battery extension assembly is available for the long run time application.

Key Features and Benefits

  • True Double-Conversion Online UPS.
  • Wide input voltage range (110~300VAC).
  • Input Power Factor correction 0.98.
  • Output Power Factor 0.80.
  • Generator compatible.
  • LCD User Interface.
  • RS-232 communication port or mini slot for USB / RS-232 / AS400 / SNMP communication
  • Self-test when UPS start.
  • Over temperature and over voltage protection.
  • Smart battery charger design for optimized battery performance.
  • Optional isolation transformer available.

Specifications

INPUT

Input AC Voltage

208/220/230/240VAC or 110/115/120/127VAC

208/220/230/240VAC

Voltage Range

Low Line Transfer

160/140/120/110VAC ±5% or 80/70/60/50VAC ±5% #1

175/150/130/110VAC ±5% #1

Low Line Comeback

168/148/128/118VAC ±5% or 84/74/64/54VAC ±5% #1

183/158/138/118VAC ±5% #1

Low Line Comeback
(Auto Restart)

168VAC ±5% or 84VAC ±5% (80%~ 100% Load)
148VAC ±5% or 74VAC ±5% (0%~ 80% Load)

180VAC ±5% (80%~ 100% Load)
155VAC ±5% (0%~ 80% Load)

High Line Transfer

300VAC ±5% or 150VAC ±5%

280VAC ±5%

High Line Comeback

290VAC ±5% or 145VAC ±5%

270VAC ±5%

Frequency Range

40~70Hz (Auto Sensing)

Power Factor Correction

≥ 0.98

≥0.99

≥ 0.95

OUTPUT

Output AC Voltage

208/220/230/240VAC or 110/115/120/127VAC

AC Voltage Regulation (Battery Mode)

±1%

±3%

Frequency Range

Synchronized Range

47~53Hz or 57~63Hz

Battery Mode

50Hz ±0.25Hz or 60Hz ±0.3Hz

Current Crest Ratio

3:1

Harmonic Distortion

Linear Load

≤ 3% THD

≤4% THD

≤3% THD

Non-Linear Load

≤6% THD

≤7% THD

≤6% THD

Transfer Time

AC Mode to Battery Mode

Zero

Inverter to Bypass

4ms (Typical)

Waveform (Battery Mode)

Pure Sinewave

Power Factor

0.8

EFFICIENCY

AC Mode

88.5%

89.3%

87%

90%

Battery Mode

83.7%

88.2%

85%

85%

BATTERY

Standard Model

Battery Type

12V9AH

12V10AH

Numbers

2

4

6

8

Typical Recharge Time

9 hours recover to 90% capacity

Charging Current (max.)

1A

Charging Voltage

27.4VDC ±1%

54.7VDC ±1%

82.1VDC ±1%

109.4VDC ±1%

Long-Run Model

Battery Type

Depending on applications

Numbers

2

4

6

8

Charging Current (max.)

1A/5A

1A/2A/4A/8A

4A/8A

4A/8A, 10A (Optional)

Charging Voltage

27.4VDC ±1%

54.7VDC ±1%

82.1VDC ±1%

109.4VDC ±1%

INDICATORS

LCD Panel

UPS Status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer, Fault Conditions

ALARM

Battery Model

Sounding every 4 seconds

Low Battery

Sounding every seconds

Overload

Sounding twice every seconds

Fault

Continuously sounding

PHYSICAL

Standard Model

Dimension (mm) DxWxH

400x146x205

397x145x220

421x190x318

426x190x318

Net Weight (kgs)

9.3

17.2

28.8

35.3

Long-Run Model

Dimension (mm) DxWxH

400x146x205

397x140x220

421x190x318

426x190x318

Net Weight (kgs)

4.8

8.9

13.5

14.3

ENVIRONMENT

Humidity

20-90% Relative Humidity @ 0~40°C (Non-Condensing)

Noise Level

Less than 45dB @ 1 Meter

Less than 55dB @ 1 Meter

Regulations

EN 62040-2:2006, EN 61000-3-2:2006+A1:2009+A2:2009, EN 61000-3-3:2008

MANAGEMENT

Smart RS232

Support Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix and MAC

Support Resources

Datasheet

Package Contents

Included

Please contact regional sales staff for details.

Warranty Period:1 year